Reset auth_fail cooldowns on NotificationManager.start()
Pedro Rico, 19/05: after reinstalling the Monitor from GitHub a real SSH/web login failure went unnotified. Root cause was the auth_fail cooldown surviving across the service restart — install_proxmenux_beta extracts the new AppImage but leaves the notification_last_sent SQLite table intact (desirable: we don't want to lose legitimate cooldowns on every update). On startup `_load_cooldowns_from_db()` then loaded the stale auth_fail row from the previous run into the in-memory cache, and `_passes_cooldown` blocked the new event. This extends the existing reset-on-start mechanism (already in place for update_summary, proxmenux_update, post_install_update, …) to also clear auth_fail rows. A security-relevant event shouldn't be silenced because the same source IP happened to fail to log in yesterday. - Rename `_UPDATE_EVENT_TYPES_RESET_ON_START` → `_EVENT_TYPES_RESET_ON_START` (the list no longer covers only update-status reports). - Rename `_reset_update_cooldowns_on_start()` → `_reset_cooldowns_on_start()` for the same reason. - Add `'auth_fail'` to the curated list. High-frequency sources (log_critical_*, disk SMART errors, …) are deliberately NOT on this list — they keep their 24h cooldown across restarts to prevent inbox floods if the user toggles the service. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
This commit is contained in:
Binary file not shown.
@@ -1 +1 @@
|
||||
0f5802ee95889df4ba011f6ae4a1897f08c1bad28d069db8b95714373c4b9426 ProxMenux-1.2.1.1-beta.AppImage
|
||||
9315f939f10353d0105a6a2cb8f3c7e21b02620a513b52ce9349a088b95751b8 ProxMenux-1.2.1.1-beta.AppImage
|
||||
|
||||
@@ -912,16 +912,15 @@ class NotificationManager:
|
||||
self._running = True
|
||||
self._stats['started_at'] = datetime.now().isoformat()
|
||||
|
||||
# Reset cooldowns for update-summary event types so the operator
|
||||
# gets a fresh "what's available now" report after every Monitor
|
||||
# deploy/restart. The 24h anti-spam cooldown serves the
|
||||
# steady-state use case (don't pester the user with the same
|
||||
# "177 packages pending" reminder every poll cycle); the
|
||||
# explicit service restart is the signal that "I want to see
|
||||
# the current state, not yesterday's silence". Non-update
|
||||
# cooldowns (auth_fail, log_critical, disk errors, …) are kept
|
||||
# so a restart doesn't unleash an inbox flood for the user.
|
||||
self._reset_update_cooldowns_on_start()
|
||||
# Reset cooldowns for the curated event-type set so the user gets
|
||||
# a fresh status report (update_summary, …) and a fresh security
|
||||
# signal (auth_fail) after every Monitor deploy/restart. The 24h
|
||||
# anti-spam cooldown serves the steady-state use case; the
|
||||
# explicit service restart is the signal that "I want to see the
|
||||
# current state, not yesterday's silence". High-frequency
|
||||
# sources (log_critical_*, disk errors, smart_*) keep their
|
||||
# cooldown across restarts to prevent inbox floods.
|
||||
self._reset_cooldowns_on_start()
|
||||
|
||||
# Ensure PVE webhook is configured (repairs priv config if missing)
|
||||
try:
|
||||
@@ -1627,12 +1626,21 @@ class NotificationManager:
|
||||
self._cooldowns[fingerprint] = now
|
||||
self._persist_cooldown(fingerprint, now)
|
||||
|
||||
# Event types whose cooldown should be cleared at every service start,
|
||||
# so the user sees a fresh "what's available right now" report after
|
||||
# any deploy. Anything not in this list keeps its 24h cooldown across
|
||||
# restarts (auth_fail, log_critical_*, disk errors, …) — preserving
|
||||
# the anti-flood guarantee for high-volume sources.
|
||||
_UPDATE_EVENT_TYPES_RESET_ON_START = (
|
||||
# Event types whose cooldown should be cleared at every service start.
|
||||
# Two reasons to be on this list:
|
||||
# (a) "Status report" events — user expects a fresh report after a
|
||||
# deploy/restart even if 24h hasn't passed. update_summary &
|
||||
# friends fall here.
|
||||
# (b) "User-actionable security events" where the cooldown surviving
|
||||
# a Monitor reinstall would silence a real attack. auth_fail —
|
||||
# if a login failure happens right after an upgrade we want it
|
||||
# delivered, not swallowed by yesterday's cooldown for the same
|
||||
# source IP.
|
||||
# Anything NOT on this list keeps its 24h cooldown across restarts
|
||||
# (log_critical_*, disk errors, smart_*, …) — preserves the
|
||||
# anti-flood guarantee for sources that can burst.
|
||||
_EVENT_TYPES_RESET_ON_START = (
|
||||
# Update-status reports
|
||||
'update_summary',
|
||||
'proxmenux_update',
|
||||
'post_install_update',
|
||||
@@ -1640,10 +1648,14 @@ class NotificationManager:
|
||||
'update_available',
|
||||
'nvidia_driver_update_available',
|
||||
'secure_gateway_update_available',
|
||||
# Security events that must not be silenced by stale cooldowns
|
||||
# following a Monitor reinstall (Pedro Rico, 19/05).
|
||||
'auth_fail',
|
||||
)
|
||||
|
||||
def _reset_update_cooldowns_on_start(self):
|
||||
"""Clear DB rows in notification_last_sent for update-type events.
|
||||
def _reset_cooldowns_on_start(self):
|
||||
"""Clear DB rows in notification_last_sent for the curated set of
|
||||
event types listed in `_EVENT_TYPES_RESET_ON_START`.
|
||||
|
||||
Fingerprint format used by `_passes_cooldown` is
|
||||
`<host>:<entity>:<event_type>[:<entity_id>]`. We match by the
|
||||
@@ -1658,7 +1670,7 @@ class NotificationManager:
|
||||
if not DB_PATH.exists():
|
||||
return
|
||||
patterns = []
|
||||
for et in self._UPDATE_EVENT_TYPES_RESET_ON_START:
|
||||
for et in self._EVENT_TYPES_RESET_ON_START:
|
||||
patterns.append(f'%:{et}:%') # entity_id non-empty form
|
||||
patterns.append(f'%:{et}') # entity_id empty / managed-install form
|
||||
where = ' OR '.join('fingerprint LIKE ?' for _ in patterns)
|
||||
@@ -1673,14 +1685,14 @@ class NotificationManager:
|
||||
# dispatch thread doesn't keep ghost cooldowns until the
|
||||
# next reload.
|
||||
for fp in list(self._cooldowns.keys()):
|
||||
for et in self._UPDATE_EVENT_TYPES_RESET_ON_START:
|
||||
for et in self._EVENT_TYPES_RESET_ON_START:
|
||||
if f':{et}:' in fp or fp.endswith(f':{et}'):
|
||||
self._cooldowns.pop(fp, None)
|
||||
break
|
||||
if deleted > 0:
|
||||
print(f"[NotificationManager] Reset {deleted} update-type cooldowns on startup")
|
||||
print(f"[NotificationManager] Reset {deleted} cooldowns on startup")
|
||||
except Exception as e:
|
||||
print(f"[NotificationManager] Failed to reset update cooldowns on start: {e}")
|
||||
print(f"[NotificationManager] Failed to reset cooldowns on start: {e}")
|
||||
|
||||