mirror of
https://github.com/MacRimi/ProxMenux.git
synced 2026-04-23 04:02:16 +00:00
Update notification service
This commit is contained in:
@@ -505,6 +505,7 @@ class JournalWatcher:
|
||||
r'user-runtime-dir@\d+', # User runtime dirs
|
||||
r'systemd-coredump@', # Coredump handlers (transient)
|
||||
r'run-.*\.mount', # Transient mounts
|
||||
r'proxmenux-monitor', # Self-referential: monitor can't alert about itself
|
||||
]
|
||||
for noise in _NOISE_PATTERNS:
|
||||
if re.search(noise, msg) or re.search(noise, unit):
|
||||
@@ -741,17 +742,20 @@ class JournalWatcher:
|
||||
def _check_backup_start(self, msg: str, syslog_id: str):
|
||||
"""Detect backup job start from journal messages.
|
||||
|
||||
Matches multiple formats:
|
||||
- pvedaemon: "INFO: starting new backup job: vzdump 110 --storage PBS-Cloud --mode stop ..."
|
||||
- pvesh: "INFO: starting new backup job: vzdump 104 --mode stop --storage PBS-Cloud ..."
|
||||
- vzdump: "starting new backup job: vzdump 110 --storage PBS-Cloud --mode stop ..."
|
||||
- vzdump: "INFO: Starting Backup of VM 110 (qemu)" (per-guest fallback)
|
||||
The message "starting new backup job: vzdump ..." is unique and
|
||||
definitive -- only a real vzdump invocation produces it. We match
|
||||
purely on message content, regardless of which service emitted it,
|
||||
because PVE uses different syslog identifiers depending on how the
|
||||
backup was triggered:
|
||||
- pvescheduler (scheduled backups via /etc/pve/jobs.cfg)
|
||||
- pvedaemon (GUI-triggered backups)
|
||||
- pvesh (CLI / API-triggered backups)
|
||||
- vzdump (per-guest "Starting Backup of VM ..." lines)
|
||||
|
||||
PVE emits from pvedaemon for scheduled backups, from pvesh for
|
||||
API/CLI-triggered backups, and from vzdump for the per-guest lines.
|
||||
Trying to maintain a whitelist of syslog_ids is fragile -- new PVE
|
||||
versions or plugins may introduce more. The message pattern itself
|
||||
is the reliable indicator.
|
||||
"""
|
||||
if syslog_id not in ('pvedaemon', 'pvesh', 'vzdump', ''):
|
||||
return
|
||||
|
||||
# Primary pattern: full vzdump command with all arguments
|
||||
# Matches both "INFO: starting new backup job: vzdump ..." and
|
||||
@@ -887,49 +891,45 @@ class JournalWatcher:
|
||||
}, entity='cluster', entity_id=node_name)
|
||||
|
||||
def _check_system_shutdown(self, msg: str, syslog_id: str):
|
||||
"""Detect system shutdown/reboot.
|
||||
"""Detect full-node shutdown or reboot.
|
||||
|
||||
Matches multiple systemd signals that indicate the node is going down:
|
||||
- "Shutting down." (systemd PID 1)
|
||||
- "System is powering off." / "System is rebooting."
|
||||
- "Reached target Shutdown." / "Reached target Reboot."
|
||||
- "Journal stopped" (very late in shutdown)
|
||||
- "The system will reboot now!" / "The system will power off now!"
|
||||
ONLY matches definitive signals from PID 1 (systemd) that prove
|
||||
the entire node is going down -- NOT individual service restarts.
|
||||
|
||||
Severity is INFO, not CRITICAL, because:
|
||||
- A planned shutdown/reboot is an administrative action, not an emergency.
|
||||
- If the node truly crashes, the monitor dies before it can send anything.
|
||||
- Proxmox itself treats these as informational notifications.
|
||||
"""
|
||||
msg_lower = msg.lower()
|
||||
# Strict syslog_id filter: only systemd PID 1 and systemd-logind
|
||||
# emit authoritative node-level shutdown messages.
|
||||
if syslog_id not in ('systemd', 'systemd-logind'):
|
||||
return
|
||||
|
||||
# Only process systemd / logind messages
|
||||
if not any(s in syslog_id for s in ('systemd', 'logind', '')):
|
||||
if 'systemd' not in msg_lower:
|
||||
return
|
||||
msg_lower = msg.lower()
|
||||
|
||||
is_reboot = False
|
||||
is_shutdown = False
|
||||
|
||||
# Detect reboot signals
|
||||
# Reboot signals -- only definitive whole-system messages
|
||||
reboot_signals = [
|
||||
'system is rebooting',
|
||||
'reached target reboot',
|
||||
'the system will reboot now',
|
||||
'starting reboot',
|
||||
]
|
||||
for sig in reboot_signals:
|
||||
if sig in msg_lower:
|
||||
is_reboot = True
|
||||
break
|
||||
|
||||
# Detect shutdown/poweroff signals
|
||||
# Shutdown/poweroff signals -- only definitive whole-system messages.
|
||||
# "shutting down" is deliberately EXCLUDED because many services emit
|
||||
# it during normal restarts (e.g. "Shutting down proxy server...").
|
||||
# "journal stopped" is EXCLUDED because journald can restart independently.
|
||||
if not is_reboot:
|
||||
shutdown_signals = [
|
||||
'system is powering off',
|
||||
'system is halting',
|
||||
'shutting down',
|
||||
'reached target shutdown',
|
||||
'reached target halt',
|
||||
'the system will power off now',
|
||||
'starting power-off',
|
||||
'journal stopped',
|
||||
'stopping journal service',
|
||||
]
|
||||
for sig in shutdown_signals:
|
||||
if sig in msg_lower:
|
||||
@@ -937,13 +937,13 @@ class JournalWatcher:
|
||||
break
|
||||
|
||||
if is_reboot:
|
||||
self._emit('system_reboot', 'CRITICAL', {
|
||||
'reason': msg[:200],
|
||||
self._emit('system_reboot', 'INFO', {
|
||||
'reason': 'The system is rebooting.',
|
||||
'hostname': self._hostname,
|
||||
}, entity='node', entity_id='')
|
||||
elif is_shutdown:
|
||||
self._emit('system_shutdown', 'CRITICAL', {
|
||||
'reason': msg[:200],
|
||||
self._emit('system_shutdown', 'INFO', {
|
||||
'reason': 'The system is shutting down.',
|
||||
'hostname': self._hostname,
|
||||
}, entity='node', entity_id='')
|
||||
|
||||
@@ -1832,11 +1832,36 @@ class ProxmoxHookWatcher:
|
||||
'hostname': pve_hostname,
|
||||
'pve_type': pve_type,
|
||||
'pve_message': message,
|
||||
'pve_title': title,
|
||||
'title': title,
|
||||
'pve_title': title or event_type,
|
||||
'title': title or event_type,
|
||||
'job_id': pve_job_id,
|
||||
}
|
||||
|
||||
# ── Extract clean reason for system-mail events ──
|
||||
# smartd and other system mail contains verbose boilerplate.
|
||||
# Extract just the actionable warning/error lines.
|
||||
if pve_type == 'system-mail' and message:
|
||||
clean_lines = []
|
||||
for line in message.split('\n'):
|
||||
stripped = line.strip()
|
||||
# Skip boilerplate lines
|
||||
if not stripped:
|
||||
continue
|
||||
if stripped.startswith('This message was generated'):
|
||||
continue
|
||||
if stripped.startswith('For details see'):
|
||||
continue
|
||||
if stripped.startswith('You can also use'):
|
||||
continue
|
||||
if stripped.startswith('The original message'):
|
||||
continue
|
||||
if stripped.startswith('Another message will'):
|
||||
continue
|
||||
if stripped.startswith('host name:') or stripped.startswith('DNS domain:'):
|
||||
continue
|
||||
clean_lines.append(stripped)
|
||||
data['reason'] = '\n'.join(clean_lines).strip() if clean_lines else message.strip()[:500]
|
||||
|
||||
# Extract VMID and VM name from message for vzdump events
|
||||
if pve_type == 'vzdump' and message:
|
||||
# PVE vzdump messages contain lines like:
|
||||
@@ -1902,8 +1927,27 @@ class ProxmoxHookWatcher:
|
||||
if pve_type == 'package-updates':
|
||||
return 'update_available', 'node', ''
|
||||
|
||||
if pve_type == 'system-mail':
|
||||
return 'system_mail', 'node', ''
|
||||
if pve_type == 'system-mail':
|
||||
# Parse smartd messages to extract useful info and filter noise.
|
||||
# smartd sends system-mail when it detects SMART issues.
|
||||
msg_lower = (message or '').lower()
|
||||
title_lower_sm = (title or '').lower()
|
||||
|
||||
# ── Filter smartd noise ──
|
||||
# FailedReadSmartErrorLog: smartd can't read the error log -- this is
|
||||
# a firmware quirk on some WD/Seagate drives, NOT a disk failure.
|
||||
# FailedReadSmartData: similar firmware issue.
|
||||
# These should NOT generate notifications.
|
||||
smartd_noise = [
|
||||
'failedreadsmarterrorlog',
|
||||
'failedreadsmartdata',
|
||||
'failedopendevice', # drive was temporarily unavailable
|
||||
]
|
||||
for noise in smartd_noise:
|
||||
if noise in title_lower_sm or noise in msg_lower:
|
||||
return '_skip', '', ''
|
||||
|
||||